October 8, 2026 | St. Johns, FL
Today we installed a brand-new Lincoln LI 1000 garage door in white, giving the home a clean, refreshed look along with improved durability and performance. To pair with the new door, we also installed a new 1 1/4 HP LiftMaster belt drive opener, known for its strong lifting power and smooth, quiet operation. ...
October 7, 2026 | Saint Augustine, FL
Customer reported the opener arm (J-arm) bracket had broken off the door. Replaced the bracket and completed a 16-point inspection; door is in good working order and running smoothly up and down. Opener is older. Advised on replacement, but the customer is moving within a year and chose to leave ...
October 6, 2026 | Saint Augustine, FL
Opener motor making abnormal noise on arrival. Attempted limit adjustment and troubleshooting; unit was not repairable. Customer approved replacement. Installed new LiftMaster 1 HP belt-drive opener with new safety sensors and new wall control. Set limits, programmed remote, and tested full operation; door running smoothly.
October 2, 2026 | Saint Augustine, FL
Customer reported the door would only close fully if the wall button was held down; otherwise it reversed back up. Inspection found failed safety sensors. Customer approved the repair, and we returned to replace the old sensors with new safety sensors and brackets. Tested door operation after install, and the ...
October 1, 2026 | Saint Augustine, FL
Customer reported cables off and door needing a reset. Reattached both cables, rewound spring, and reset door. Door operating well. Offered new springs and new tracks; customer declined, as he plans to install a commercial-style chain-lift door down the road and only wants the current door working for now. Customer ...
September 30, 2026 | Saint Augustine, FL
Customer requested repairs on doors #101 and #110. Both doors had cables off track and off the pulleys. Door #101 also had a roller out of the track and a damaged lock, which we repaired. We fully reset both doors, tightened both tracks, and reset and re-tensioned the cables. Both doors are now ...
September 29, 2026 | Jacksonville, FL
Customer reported the J-arm had pulled away from the door. With customer approval, tech repositioned the J-arm bracket and secured it with new bolts into a fresh, solid section of the door to ensure a secure hold. Door was tested through multiple open/close cycles and is operating normally. Customer ...
September 28, 2026 | Palm Coast, FL
Completed $123 WAGS Plan 16-point inspection and lubrication. Double door is paired with a low-HP opener that's undersized for the door; recommended upgrading to a higher-horsepower unit. Customer agrees the current opener struggles to lift the door and is very interested in replacing it at a later date.
September 25, 2026 | Saint Augustine, FL
Replaced opener installed from previous day. Before removal, found safety sensor and wall button wires crossed, causing indicator lights to come on but preventing operation. Rewired correctly; opener programmed and operated properly from wall button and sensors. Programmed additional remote and keypad, set up Wi-Fi, and walked customer through all ...
September 24, 2026 | Saint Johns, FL
Installed new LiftMaster 2220L chain-drive opener with new safety sensors, wall button and chain rail; programmed open/close limits and force settings and confirmed proper operation. Installed two sets of nylon rollers and two surge protectors. Performed maintenance and lubrication on both doors and the existing 2009 chain-drive opener (single-car door), ...
September 23, 2026 | Saint Augustine, FL
Four-door maintenance visit. Replaced all rollers on every door, 40 in total. Lubricated all rollers and hinges, then checked and tightened the belts on each opener. Post-service test: all four doors open and close smoothly with minimal noise. Customer was satisfied with the results and paid in full by check. Recommend ...
September 22, 2026 | Saint Augustine, FL
Customer requested a garage door opener replacement upon arrival, as the existing unit was no longer working. Per the customer's request, installed a new 1 HP belt-drive opener with a 7 ft rail. Replaced all rollers for smoother, quieter travel, reset the open and close limits, and ran the door through full ...
September 21, 2026 | Ponte Vedra, FL
Upon arrival, found the customer's TorqueMaster system had a broken spring inside the tube, leaving the door unable to open. After discussing options, the customer requested a torsion conversion. Completed the conversion, performed a full maintenance and safety check, and lubricated all hinges and rollers. Door is operating properly.
September 18, 2026 | Saint Augustine, FL
Arrived on site and found one TorqueMaster system failed with broken, cut cables. Customer requested torsion conversions on both garage doors (one single-car, one double-car). Converted both doors from TorqueMaster to standard torsion spring systems, set the opener limits, and confirmed both doors are in good working order. Customer paid ...